BS1363 Figure 10 High Temperature Pressure Test Apparatus SC-BS1363-F10

BS1363-1 / BS1363-3 Figure 10 High Temperature Pressure Test Apparatus

SC-BS1363-F10

Product Overview

This apparatus is manufactured in accordance with BS 1363-1:1995 + Amd 1, 2, 3 — “13 A plugs, socket-outlets, adaptors and connection units — Part 1: General requirements” — and BS 1363-3, Figure 10. It is used for the high-temperature pressure test of the insulating sleeves of BS-standard plug pins: to verify the ability of the insulating-sleeve material of plug pins to resist blade-pressure deformation under simulated overheat conditions. It is a dedicated apparatus for type tests, outgoing inspections and third-party certification testing of BS 1363 plug products.

Construction and Key Parameters

  • Blade: width 0.70+0.050 mm, front-end radius R 3 mm ± 0.1 mm
  • Load: combined weights exert a pressure of 2.5 N0-0.1 on the specimen via the blade
  • Number of specimens: three pin specimens each time; one of them shall not have been used for the wear test of Clause 12.17.3
  • Support & positioning: the pin specimen is fixed horizontally on the support as shown in Figure 10, with the blade indentation located at the middle of the insulating sleeve
  • Material: main body made of stainless steel — heat-resistant and corrosion-resistant; weights and blade are heat-treated for dimensional stability

Test Method (per BS 1363-1 Clause 12.17.4)

Mount the insulating-sleeve specimen of the pin under test on this apparatus as required by Figure 10 so that the blade applies a constant pressure of about 2.5 N to the specimen. Then place the whole apparatus (with specimen) into a heating chamber and keep it at 200 °C for 120 min. After the specified time, remove the specimen immediately and immerse it in room-temperature water to cool. After cooling, measure the remaining thickness of the insulating sleeve at the indentation; the thickness reduction shall not exceed 50 %.

Applicable Standards

BS 1363-1:1995 + Amd 1, 2, 3 — Clause 12.17.4 / Figure 10; BS 1363-3.

Standard Drawing

BS 1363-1 Figure 10 Apparatus for pressure test at high temperatures
BS 1363-1 Figure 10 — Apparatus for pressure test at high temperatures (standard drawing)

Product Photos

BS1363 Figure 10 High Temperature Pressure Test Apparatus photo 1
BS1363 Figure 10 High Temperature Pressure Test Apparatus — photo 1
BS1363 Figure 10 High Temperature Pressure Test Apparatus photo 2
BS1363 Figure 10 High Temperature Pressure Test Apparatus — photo 2
BS1363 Figure 10 High Temperature Pressure Test Apparatus photo 3
BS1363 Figure 10 High Temperature Pressure Test Apparatus — photo 3
BS1363 Figure 10 High Temperature Pressure Test Apparatus photo 4
BS1363 Figure 10 High Temperature Pressure Test Apparatus — photo 4
BS1363 Figure 10 High Temperature Pressure Test Apparatus photo 5
BS1363 Figure 10 High Temperature Pressure Test Apparatus — photo 5

Related Products

Scroll to Top