All Products

IEC61032 Probe B With Dia 50mm Circular Stop Face probe IEC 61010-1 Figure B.2

Jointed Test Finger of IEC 61010-1 Figure B.2
Product Description

IEC61032 Probe B With Dia 50mm Circular Stop Face probe IEC 61010-1 Figure B.2 SC-F2B-A

Jointed Test Finger of IEC 61010-1 Figure B.2
Jointed Test Finger of IEC 61010-1 Figure B.2

Standards & Clauses:

The test probe complies with the standard IEC 61032 figure 2, and required by IEC 60335-1 clause 20.2, etc.

This test probe that is similar to test probe B of IEC 61032 but having a circular stop face with a diameter of 50 mm, instead of the non-circular face, is intended to verify that the moving parts of appliances shall, as far as is compatible with use and working of the appliance, to be positioned or enclosed to provide adequate protection against personal injury in normal use.

 

Samples and Restrictions:

Household appliances, electrical accessories, lamps, etc.

Application:

To verify

a) protection of persons against access to hazardous parts inside the enclosure;

b) protection of the equipment inside the enclosure against ingree of solid foreign object.

Test Principle:

The similar to test probe B of IEC 61032 but having circular stop face with a diameter of 50 mm is used to distinguish the different protection levels of the electrical enclosure. After the current or force is applied to the probe, whether the probe can contact the live parts or internal parts, to determines whether the specimen is qualified or not.

Structure:

This test finger probe consists of dito,finger,base and insulated handle which simulates the characteristics of the human hand. It has two movable joints, which can be curved at 90°.
Customizable: it can be used for anti-electric shock test when equipped with pluggable banana plugs and amphenol connector at the end of the handle, or used for enclosure protection test when open threaded hole of M6 at the end of the handle (connected with pull and push force gauge).

Technical Parameters:

Parameters /Model SC-F2B SC-F2B-A
Name Standard test finger Circular baffle test finger
1 30±0.2 30±0.2
2 60±0.2 60±0.2
3 80±0.2 80±0.2
4 180±0.2 180±0.2
5 R2±0.05 R2±0.05
6 S4±0.05 S4±0.05
7 37o  0 -10’ 37o   0 -10’
8 14 o  0 -10’ 14 o  0 -10’
9 Ф12 0 -0.05 Ф12 0 -0.05
10 Ф50 Ф50
11 20±0.2 —-
12 Ф75±0.2 Ф75±0.2
13 5±0.5 5±0.5
14 —- —-
15 IEC61032.1 IEC60335-1