EN 50636-2-100 Figure 2 & ISO 5395-3 Figure B.4 Adult Arm Probe Set SC-50636K4 (4 pcs)

EN 50636-2-100 Figure 2 & ISO 5395-3:2013 Figure B.4 Adult Arm Probe Set SC-50636K4 (4 pcs)

SC-50636K4 is a four-piece adult arm probe set for risk assessment of power garden tools and pedestrian-controlled lawnmowers. It contains two EN 50636-2-100 Figure 2 adult arm probes and two ISO 5395-3:2013 Figure B.4 adult arm test probes, supplied in a dedicated carrying case.

The two types look alike but are machined to the critical dimensions of their own standard figures and are not interchangeable. The Figure 2 probe has a nylon handle, a metal arm with a 90° bent tip and a pivoting knuckle, and a Ø60 stop disc that limits insertion depth. The Figure B.4 probe is a ball-nose type: Ø12 ball tip, Ø20 / Ø28 stepped diameters, Ø50 stop disc and 180 mm effective insertion depth.

SC-50636K4 adult arm probe set 4 pcs
SC-50636K4 adult arm probe set (4 pcs) with carrying case

Set contents

No. Model Description Applicable standard Qty
1 SC-50636F2 Adult arm test probe EN 50636-2-100 Figure 2 / EN 13683-2003 Clause 5.2.1.3 Figure 5 / IEC 62841-4-6:2022 Figure 105 2
2 SC-5395B4 Adult arm test probe, ball nose ISO 5395-3:2013 Figure B.4 2

Applicable standards

  • EN 50636-2-100 Figure 2 – adult arm probe
  • EN 13683-2003 Clause 5.2.1.3 Figure 5 – arm probe for tortuous path guarding
  • IEC 62841-4-6:2022 Clause 19.101.3 Figure 105 – adult arm probe
  • ISO 5395-3:2013 Figure B.4 – test probe for cutting-means guarding

Specifications

Item Main dimensions
Figure 2 adult arm (SC-50636F2) Ø12 / Ø50 / Ø60 stop disc; tip bent 90°; 60 / 80 / 180 mm; 550 / 850 mm overall
Figure B.4 adult arm (SC-5395B4) Ø12 ball tip; Ø20 / Ø28 stepped body; Ø50 stop disc; 180 mm insertion depth; 30° chamfer; SR3
Handle Nylon, polished metal probe and joints

Test procedure

  1. Select the probe to match the equipment: Figure 2 adult arm for garden tool cutting means, Figure B.4 for lawnmower cutting-means guarding.
  2. Insert the probe into the opening and push along the tortuous path until the stop disc is reached.
  3. Apply the force specified in the relevant clause; rotate the knuckle or vary the approach angle to cover the reachable envelope of a human arm.
  4. Observe whether the probe tip can touch blades or other hazardous moving parts. Contact means the guarding fails and the opening must be reduced, the path lengthened or a deflector added.

Standard figures

EN 50636-2-100 Figure 2 adult arm probe standard drawing
EN 50636-2-100 Figure 2 adult arm probe – standard dimensions
ISO 5395-3 Figure B.4 test probe standard drawing
ISO 5395-3:2013 Figure B.4 test probe – standard dimensions

Related products

Scroll to Top