Product details:
The UL1310 S3252 test probe conforms to standard requirement of UL1310 Fig 16.4(S3252). It is used for testing accessibility to hazardous moving parts such as access to fan blades through a fan finger guard.
The handle is nylon while the tip is stainless steel.

Product Parameters:
1. Probe Total Length: 114.3mm (4.5 inches)
2. Tail Probe Diameter: 25.4mm (1.0inch)
3. Head Probe Diameter: 50.8mm (2.0 inches)
4. Former Head Radius: R 14.3mm (0.25inch)
5. Standard: UL1310 figure 16.4
Standards: