Contact test gauge to BS 1363-2 Figure 12. Used with the Figure 13 test circuit to verify that the contacts of a socket-outlet make reliable electrical contact with standard pins.
Product identification
| Item | Specification |
|---|---|
| Model | SC-BS1363-F12 |
| Figure | Figure 12 – Contact test gauge |
| Product | BS1363 Figure 12 Contact Test Gauge |
Product photos




Application and test method
Insert the gauge into the socket-outlet and connect per Figure 13. A 40 V test supply is applied between the socket contacts and the gauge; the indicator lamps show whether each pole makes contact. All three poles shall indicate contact with the pins fully inserted.
Technical data
| Item | Specification |
|---|---|
| Standard | BS 1363-2:1995 incl. amendments |
| Figure | Figure 12 – Contact test gauge |
| Used with | Figure 13 – Test apparatus and circuit |
| Test voltage | 40 V |
| Socket type | 13 A three-pin socket-outlet |
| Pin material | Hardened stainless steel, polished contact faces |
| Body | Insulating engineering plastic with metal screen |
| Marking | BS1363 Figure 12 + serial number |
Standard drawing

Handling and maintenance
Check the wiring of the test circuit and the lamps before testing. Contamination on the gauge pins changes the result, so clean them after every use.
For the complete BS 1363 range of gauges and test apparatus, contact Guangzhou Shice Instrument for selection and quotation.