BS1363 Figure 12 Contact Test Gauge SC-BS1363-F12

BS1363 Figure 12 Contact test gauge standard drawing

Contact test gauge to BS 1363-2 Figure 12. Used with the Figure 13 test circuit to verify that the contacts of a socket-outlet make reliable electrical contact with standard pins.

Product identification

Item Specification
Model SC-BS1363-F12
Figure Figure 12 – Contact test gauge
Product BS1363 Figure 12 Contact Test Gauge

Product photos

SC-BS1363-F12 - Contact test gauge body
Contact test gauge body
SC-BS1363-F12 - Front view, stamped BS1363 Figure 12
Front view, stamped BS1363 Figure 12
SC-BS1363-F12 - Pin side
Pin side
SC-BS1363-F12 - Angled view
Angled view

Application and test method

Insert the gauge into the socket-outlet and connect per Figure 13. A 40 V test supply is applied between the socket contacts and the gauge; the indicator lamps show whether each pole makes contact. All three poles shall indicate contact with the pins fully inserted.

Technical data

Item Specification
Standard BS 1363-2:1995 incl. amendments
Figure Figure 12 – Contact test gauge
Used with Figure 13 – Test apparatus and circuit
Test voltage 40 V
Socket type 13 A three-pin socket-outlet
Pin material Hardened stainless steel, polished contact faces
Body Insulating engineering plastic with metal screen
Marking BS1363 Figure 12 + serial number

Standard drawing

SC-BS1363-F12 standard drawing
Figure 12 – Contact test gauge – standard drawing

Handling and maintenance

Check the wiring of the test circuit and the lamps before testing. Contamination on the gauge pins changes the result, so clean them after every use.

For the complete BS 1363 range of gauges and test apparatus, contact Guangzhou Shice Instrument for selection and quotation.