| 1 |
Gauge for shortest contact distance and minimum withdrawal force of contact jacks |
Lehre 2A |
| 2 |
Gauge for spacing of two pole openings of socket-outlet |
Lehre 3 |
| 3 |
Gauge for insertability of two-pole plug with side earth contact |
Lehre 4 |
| 4 |
Gauge for testing the interval of first contact closure |
Lehre 5A |
| 5 |
Gauge for diameter of 16A pins |
Lehre 6b, 6d |
| 6 |
Gauge for distance of 16A pins (7A, 7B) |
Lehre 7A, 7B |
| 7 |
Gauge for maximum width of contact openings |
Lehre 8 |
| 8 |
Gauge for testing interchangeability of plugs |
Lehre 9 |
| 9 |
Non-insertable gauge for single pole A |
Lehre 10A |
| 10 |
Non-insertable gauge for single pole B |
Lehre 10B |
| 11 |
Non-insertability of two-pole plug without earthing contact |
Lehre 11 |
| 12 |
Gauge for impossibility of inserting single pole of plug (250g+750g weights) |
Lehre 12 |
| 13 |
Probe for non-touchability of shutters 1N |
Lehre 13 |
| 14 |
Gauge for testing contacts earthed on both sides |
Lehre 14 |
| 15 |
Probe for non-touchability of shutters 20N |
Lehre 15 |
| 16 |
Gauge for maximum single pin hanging weight of earth hole (25N weight) |
Lehre 16e |
| 17 |
Maximum withdrawal force gauge 16A |
Lehre 16a |
| 18 |
Torque test of plug pins (0.4 N·m) |
VDE0620-1 cl.24.2 |
| 19 |
16A temperature rise plug gauge |
Bild 16a |
| 20 |
Apparatus for measuring contact pressure of side earthing contacts |
Bild 14 |
| 21 |
Test gauge (apparatus) for side earthing contacts |
Bild 43 |
| 22 |
150N compression test apparatus (Lehre 14 inserted with 150N for 1 min) |
DIN VDE0620-1 cl.10.6.1 |