TIS 166-2549 Figure A.1 Gauge for checking impossibility of single-pole insertion of plugs
Product No: SC-TIS166-2549-FA.1-2 (2-pin, unearthed) · SC-TIS166-2549-FA.1-3 (3-pin, earthed)
Standard: TIS 166-2549 – Thai Industrial Standard for Plugs and Socket-Outlets for Household and Similar Purposes: Plugs and Socket-Outlets with Rated Voltage not Exceeding 250 V. Appendix A of the standard defines the gauges: Figures A.1 to A.5 check the dimensions of the socket-outlet, Figures A.6 and A.7 check the withdrawal force, and Figures A.8 to A.10 are the additional gauges for socket-outlets.
Application
The Figure A.1 gauge verifies that it is impossible to touch a live contact tube of a socket-outlet with a single plug pin. The test is carried out with the engagement face of the socket-outlet in a horizontal position and with all passages open.
The gauge is offered in every possible position of the socket opening. At no position shall a single pin reach the contact tube of the socket. Contact is indicated electrically with a 40–50 V indicator, so any touch of a live part is signalled at once.
Two versions are supplied: a 2-pin gauge for unearthed socket-outlets and a 3-pin gauge for earthed socket-outlets, so that the earth passage can be checked in the same way.
Construction
- Body and pins in corrosion-resistant stainless steel with sufficient mechanical strength
- Mass of the gauge 200 ± 5 g, as required by Figure A.1
- Contact pins machined to the entry-hole layout of the socket-outlet, positions and diameters per Figure A.1
- 2-pin version for unearthed socket-outlets, 3-pin version for earthed socket-outlets
- Flexible test lead for a 40–50 V electronic indicator
Key specification
| Product No | SC-TIS166-2549-FA.1-2 (2-pin) / SC-TIS166-2549-FA.1-3 (3-pin) |
| Reference | TIS 166-2549 Figure A.1, clause 9.101 |
| Gauge mass | 200 ± 5 g |
| Test indicator | 40–50 V electronic indicator |
| Material | Stainless steel, corrosion-resistant |
| Test position | Engagement face horizontal, all passages open |
Product pictures





Standard drawing

Related TIS 166-2549 gauges
- TIS 166-2549 Figure A.2 Gauge for testing the contact of the live contact tube
- TIS 166-2549 Figure A.3 Gauge for testing earthing contact before live contacts
- TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube
- TIS 166-2549 Figure A.5 Gauge for initial testing dimensions of the socket-outlet
- TIS 166-2549 Figure A.6 Gauge for testing maximum withdrawal force
- TIS 166-2549 Figure A.7 Gauge for testing minimum withdrawal force
- TIS 166-2549 Figure A.8 Gauge for testing earthing contact before current-carrying contacts for flat-round pin socket-outlet
- TIS 166-2549 Figure A.9 Gauge for testing maximum withdrawal force for flat-round pin socket-outlet
- TIS 166-2549 Figure A.10 Gauge for testing minimum withdrawal force of current-carrying pole for flat-round pin socket-outlet
All Thai TIS 166-2549 gauges: TIS 166-2549 gauges for plugs and socket-outlets.