TIS 166-2549 Figure A.5 Gauge for initial testing dimensions of the socket-outlet
Product No: SC-TIS166-2549-FA.5-1 (round pin and flat-round pin socket) · SC-TIS166-2549-FA.5-2 (flat-round pin socket)
Standard: TIS 166-2549 – Thai Industrial Standard for Plugs and Socket-Outlets for Household and Similar Purposes: Plugs and Socket-Outlets with Rated Voltage not Exceeding 250 V. Appendix A of the standard defines the gauges: Figures A.1 to A.5 check the dimensions of the socket-outlet, Figures A.6 and A.7 check the withdrawal force, and Figures A.8 to A.10 are the additional gauges for socket-outlets.
Application
The Figure A.5 gauge checks the dimensions of a socket-outlet in the initial condition, before the endurance and ageing tests.
Version A.5-1 covers round pin and flat-round pin socket-outlets; version A.5-2 covers flat-round pin socket-outlets. The correct profile is entered into the socket openings with the shutters open, and the gauge shall enter freely without force over the whole engagement depth.
Dimensions and tolerances of the gauge are those of TIS 166-2549 Figure A.5 (1) and Figure A.5 (2).
Construction
- Body in corrosion-resistant stainless steel, as required by Figure A.5
- Profile machined to the dimensions of Figure A.5 (1) for round pin and flat-round pin socket-outlets
- Separate version for flat-round pin socket-outlets, Figure A.5 (2)
- Lifting ring for handling and for withdrawal
Key specification
| Product No | SC-TIS166-2549-FA.5-1 / SC-TIS166-2549-FA.5-2 |
| Reference | TIS 166-2549 Figure A.5 (1) and A.5 (2), clause 9.101 |
| A.5-1 | Round pin and flat-round pin socket-outlets |
| A.5-2 | Flat-round pin socket-outlets |
| Use | Initial dimensional check before endurance and ageing tests |
| Material | Stainless steel, corrosion-resistant |
Product pictures





Standard drawing


Related TIS 166-2549 gauges
- TIS 166-2549 Figure A.1 Gauge for checking impossibility of single-pole insertion of plugs
- TIS 166-2549 Figure A.2 Gauge for testing the contact of the live contact tube
- TIS 166-2549 Figure A.3 Gauge for testing earthing contact before live contacts
- TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube
- TIS 166-2549 Figure A.6 Gauge for testing maximum withdrawal force
- TIS 166-2549 Figure A.7 Gauge for testing minimum withdrawal force
- TIS 166-2549 Figure A.8 Gauge for testing earthing contact before current-carrying contacts for flat-round pin socket-outlet
- TIS 166-2549 Figure A.9 Gauge for testing maximum withdrawal force for flat-round pin socket-outlet
- TIS 166-2549 Figure A.10 Gauge for testing minimum withdrawal force of current-carrying pole for flat-round pin socket-outlet
All Thai TIS 166-2549 gauges: TIS 166-2549 gauges for plugs and socket-outlets.