TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube

TIS 166-2549 Figure A.4 gauges C1/C2/C3 for resilience and contact force of the contact tube

TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube

Product No: SC-TIS166-2549-FA.4-C1 · FA.4-C2 · FA.4-C3 (gauges C1, C2 and C3)

Standard: TIS 166-2549 – Thai Industrial Standard for Plugs and Socket-Outlets for Household and Similar Purposes: Plugs and Socket-Outlets with Rated Voltage not Exceeding 250 V. Appendix A of the standard defines the gauges: Figures A.1 to A.5 check the dimensions of the socket-outlet, Figures A.6 and A.7 check the withdrawal force, and Figures A.8 to A.10 are the additional gauges for socket-outlets.

Application

The three gauges C1, C2 and C3 check the resilience of the contact tubes and the contact pressure of a socket-outlet. The shutters are kept open during the whole test and any grease is removed from the pins before the test.

Gauge C1 is inserted perpendicular to the engagement face with a force not exceeding 50 N and shall not come out of the socket-outlet under its own weight.

Gauges C2 and C3 are then inserted one after the other in the same way. Each of them shall not come out of the socket-outlet under its own weight. The socket-outlet may be placed in the most unfavourable position for each step.

Construction

  • Three gauges C1, C2 and C3 in corrosion-resistant stainless steel
  • Pin diameter and mass matched to the table of Figure A.4 (see specification below)
  • Flat contact face so that the 50 N insertion force can be applied perpendicular to the engagement face
  • Engraved with the gauge designation C1 / C2 / C3

Key specification

Product No SC-TIS166-2549-FA.4-C1 / FA.4-C2 / FA.4-C3
Reference TIS 166-2549 Figure A.4, clause 9.101
Gauge C1 A = 4.95 ± 0.05 mm, mass 400 ± 5 g
Gauge C2 A = 4.74 ± 0.05 mm, mass 200 ± 5 g
Gauge C3 A = 4.00 ± 0.05 mm, mass 200 ± 5 g
Insertion force Maximum 50 N, perpendicular to the engagement face
Acceptance No gauge shall come out of the socket under its own weight

Product pictures

TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube - Gauges C1, C2 and C3 - set view
Gauges C1, C2 and C3 – set view
TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube - Gauges C1, C2 and C3 - upright
Gauges C1, C2 and C3 – upright
TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube - Gauges C1, C2 and C3 - pin detail
Gauges C1, C2 and C3 – pin detail
TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube - Gauges C1, C2 and C3 - column view
Gauges C1, C2 and C3 – column view
TIS 166-2549 Figure A.4 Gauge for testing resilience and contact force of the contact tube - Gauges C1, C2 and C3 - engraved bodies
Gauges C1, C2 and C3 – engraved bodies

Standard drawing

TIS 166-2549 Figure A.4 standard drawing
Figure A.4 standard drawing – gauges C1, C2 and C3 for resilience and contact force (dimensions in mm)

Related TIS 166-2549 gauges

All Thai TIS 166-2549 gauges: TIS 166-2549 gauges for plugs and socket-outlets.